Reference Only
DVL 1000-UI
DVL 1000 with universal input
Datasheet
DVL 1000-UI Datasheet
Product Description
DVL 1000 with universal input
Technical Specifications
| Attribute | Description |
|---|---|
| Accuracy | 85 percent |
| Technology | Closed Loop |
| Output Signal | Voltage |
| Supply Voltage | Plus or Minus 15 Volts |
| Measurement Range | 0 to 1000 Volts |
| Dielectric Strength | 5 Kilovolts |
| Operating Temperature | Negative 25 Degrees Celsius to Positive 85 Degrees Celsius |
| Primary Nominal Rms Voltage | 1000 Volts |