Reference Only
CAS 50-NP
Fluxgate open-loop, ±50A nominal, multi-range, PCB
Datasheet
CAS 50-NP Datasheet
Product Description
Fluxgate open-loop, ±50A nominal, multi-range, PCB
Technical Specifications
| Attribute | Description |
|---|---|
| Output Type | Current |
| Package Type | PCB Mount |
| Technology Type | Closed Loop |
| Accuracy Percentage | Plus or minus 0.9 percent |
| Linearity Percentage | Less than 0.1 percent |
| Supply Voltage Volts | Plus or minus 15 Volts |
| Measuring Range Amperes | 0 to plus or minus 50 Amperes |
| Response Time Microseconds | Less than 1 microsecond |
| Isolation Voltage Kilovolts | 3 Kilovolts |
| Aperture Diameter Millimeters | 8 millimeters |
| Operating Temperature Range Celsius | Minus 25 degrees Celsius to plus 85 degrees Celsius |