Reference Only
ARU-B100-D125/SP4
Rogowski + integrator, 125mm, special version
Datasheet
ARU-B100-D125/SP4 Datasheet
Product Description
Rogowski + integrator, 125mm, special version
Technical Specifications
| Attribute | Description |
|---|---|
| Accuracy | 0.5 percent |
| Linearity | 0.1 percent |
| Technology | Open Loop |
| Response Time | 1 microsecond |
| Offset Voltage | 5 millivolts |
| Output Voltage | 4 volts |
| Supply Voltage | Plus or Minus 12 volts to Plus or Minus 15 volts |
| Dielectric Strength | 4.3 kilovolts |
| Measured Current Rms | 100 Amperes |
| Measured Current Peak | 125 Amperes |
| Operating Temperature | Negative 40 degrees Celsius to Positive 85 degrees Celsius |