Reference Only
0918106054
Force sensor based on strain gauge technology.
Datasheet
0918106054 Datasheet
Product Description
The 0918106054 FORCE SENSOR, manufactured by ANGST+PFISTER (SMARTEC), employs advanced strain gauge technology to deliver precise and dependable force measurements. This sensor is designed for integration into a wide array of applications, including industrial automation, robotics, and research equipment. Its robust construction ensures long-term reliability and consistent performance even in demanding environments. Supreme Components International, an authorised distributor of ANGST+PFISTER (SMARTEC) components, provides access to this high-quality sensor with full technical support and product expertise. Benefit from accurate force sensing capabilities with the 0918106054, available now through Supreme Components International. Trust in our commitment to quality and authenticity for all your electronic component needs.
Technical Specifications
| Attribute | Description |
|---|---|
| Creep | Less than or equal to plus or minus 0.5 percent of full scale per 30 minutes |
| Material | Aluminum |
| Hysteresis | Less than or equal to plus or minus 0.5 percent of full scale |
| Rated Output | 1.0 plus or minus 0.1 millivolts per volt |
| Zero Balance | Less than or equal to plus or minus 2 percent of full scale |
| Non Linearity | Less than or equal to plus or minus 0.5 percent of full scale |
| Repeatability | Less than or equal to plus or minus 0.2 percent of full scale |
| Safe Overload | 150 percent of full scale |
| Measuring Range | 0 to 500 Newtons |
| Input Resistance | 350 plus or minus 10 Ohms |
| Protection Class | IP65 |
| Output Resistance | 350 plus or minus 5 Ohms |
| Ultimate Overload | 300 percent of full scale |
| Excitation Voltage | 3 to 10 Volts DC |
| Electrical Connection | Cable |
| Insulation Resistance | Greater than or equal to 5000 Mega Ohms at 50 Volts DC |
| Operating Temperature | -20 degrees Celsius to +60 degrees Celsius |
| Compensated Temperature | 0 degrees Celsius to +50 degrees Celsius |
| Temperature Effect On Span | Less than or equal to plus or minus 0.05 percent of full scale per degree Celsius |
| Temperature Effect On Zero | Less than or equal to plus or minus 0.05 percent of full scale per degree Celsius |